News & Topics

Oct 14, 2015

Supporting Rapid Testing and Diagnosis During the Virus Season
-ARKRAY, Inc. Releases RS Virus and Adenovirus Kits-

ARKRAY Inc. will release the SPOTCHEM i-Line RSV and SPOTCHEM i-Line Adeno virus test kits for sale to medical institutions nationwide on October 21, 2015 (Wednesday). They can quickly determine RS virus and adenovirus, and will support the testing and diagnosis of viral infections during epidemic seasons.

RS virus (RSV) is the main virus causing the acute respiratory tract infections in infants that are prevalent every winter. Furthermore, Adenovirus is one of the viruses causing the common cold syndrome (pool fever, PCF). They are both characterized by being highly infectious diseases that occur in epidemics among infants and children. Due to the high probability of causing group infections and nosocomial infections, rapid detection of the presence of an infection and taking appropriate steps are considered to be important.

The SPOTCHEM i-Line RSV and SPOTCHEM i-Line Adeno being released by ARKRAY Inc. (hereafter, ARKRAY) are in-vitro diagnostic agents for the SPOTCHEM IL SL-4720 densitometry analyzer. RSV in fluids sampled with a nasal swab or nasal aspiration, and Adenovirus is detected in fluids sampled with a throat swab. Determination can be made using the device or visually, and results can be obtained in 5 to 15 minutes. Performing on-the-spot testing in hospitals is believed to be useful for reducing the burden on patients such as shortening waiting times, improving the efficiency of medical care and reducing opportunities for the transmission of viruses.

With the release of the product, there are six products*1 in the SPOTCHEM i-Line series of testing kits. ARKRAY will continue work to expand the lineup of test items to contribute to quick diagnosis and appropriate treatment in treatment sites.

*1 Influenza virus A/B, CRP, Group A streptococcal antigen, IgE antibody (egg white, egg yolk, ovomucoid, milk, wheat, cedar pollen, cat dander, Dermatophagoides pteronyssinus), RS Virus, Adenovirus


151014_01_e.jpg
SPOTCHEM i-Line RSV
20151014_02_e.jpg
Test cartridge
RSV(Top)
Adenovirus(Bottom)

Reference Materials

ARKRAY has been selling the SPOTCHEM series of simple testing devices for point of care (POC) testing in clinics since 1988. The SPOTCHEM IL SL-4720 is a small rapid testing device that automates immunochromatic testing. This instrument was developed with the idea of using an instrument to conduct tests easily, quickly and accurately in order to improve the quality of treatment from that of the previous visual inspection technique.
By entering the patient name in the reagent cartridge for the device, patient names will be printed out with the measurement results, reducing the risk of mistaking samples. Also, the footprint of the device is smaller than an A4 sheet of paper, so it does not take up much space.

151014_03_e.jpg
Measurement using the SPOTCHEM IL SL-4720

Product Overview: SPOTCHEM i-Line RSV

Name SPOTCHEM i-Line RSV
Release Date October 21, 2015 (Wednesday)
Specifications
  Meas. Target Fluids sampled by nasal swab or nasal aspiration
  Meas. Items RS virus
  Meas. Instrument Densitometry analyzer SPOTCHEM IL SL-4720
  Meas. Principle Immunochromatographic method
  Meas. time Approx. 5 to 15 minutes per sample
  Storage Method 2 to 30℃ (do not freeze), 18 months
Packaging Unit 10 units (10 tests)
Test cartridges, specimen extraction fluid (extraction tubes), filter nozzles
Approval No. 22400AMX00767000
Product Category In-vitro Diagnostic Agent
Classification Class III

Product Overview: SPOTCHEM i-Line Adeno

Name SPOTCHEM i-Line Adeno
Release Date October 21, 2015 (Wednesday)
Specifications
  Meas. Target Fluid from throat swab
  Meas. Items Adenovirus
  Meas. Instrument Densitometry analyzer SPOTCHEM IL SL-4720
  Meas. Principle Immunochromatographic method
  Meas. time Approx. 5 to 15 minutes per sample
  Storage Method 2 to 30℃ (do not freeze), 18 months
Packaging Unit 10 units (10 tests)
Test cartridges, specimen extraction fluid (extraction tubes), filter nozzles
Approval No. 22700AMX00677000
Product Category In-vitro Diagnostic Agent
Classification Class III

This product will be sold through ARKRAY Marketing, Inc. (ARKRAY, Inc.'s distributor in Japan).
This product is only available in Japan and is not sold in other countries.